"Based on domestic market and expand abroad business" is our progress strategy for Rotational Moment, Hall Effect, Fabry Perot Interferometer, The continual availability of high grade products in combination with our excellent pre- and after-sales service ensures strong competitiveness in an increasingly globalized market.
China Wholesale Double beam infrared spectrometer Suppliers – LADP-14 Determining Specific Charge of Electron – Advanced Model – Labor Detail:

Experiments

1. Quantitatively measure the rules of electron movement in both electric and magnetic field.

    a) Electrical deflection: electron + transversal electric field

b) Electrical focusing: electron + longitudinal electric field

c) Magnetic deflection: electron + transversal magnetic field

d) Spiral motion magnetic focusing: electron + longitudinal magnetic field

2. Determine e/m ratio of an electron and verify the polar coordinate equation of electron spiral motion.

3. Measure geomagnetic component.

The instruction manual contains comprehensive materials including experimental configurations, principles, step-by-step instructions and some experimental results. Please click Experiment Theory and Contents to find more information about this apparatus.

 

Specifications

 

Description Specifications
Filament voltage 6.3 VAC; current 0.15 A
High voltage UA2 600 ~ 1000 V
Deflecting voltage -55 ~ 55 V
Grid voltage UA1 0 ~ 240 V
Control grid voltage UG 0 ~ 50 V
magnetization current 0 – 2.4 A
Solenoid parameters
Longitudinal coil (long) length: 205 mm; inner dia: 90 mm; outer dia: 95 mm; number of turns: 1160
Transversal coil (small) length: 20 mm; inner dia: 60 mm; outer dia: 65 mm; number of turns: 380
Digital meters 3-1/2 digits
Sensitivity of electrical deflection Y: ≥0.38 mm/V; X:  ≥0.25 mm/V
Sensitivity of magnetic deflection Y: ≥0.08 mm/mA
e/m measurement error ≤5.0%

 

Parts List

 

Description Qty
Main unit 1
CRT 1
Long coil (solenoid coil) 1
Small coil (deflection coil) 2
Division screen 1
Cable 2
Instructional manual 1

Product detail pictures:

China Wholesale Double beam infrared spectrometer Suppliers –  LADP-14 Determining Specific Charge of Electron – Advanced Model – Labor detail pictures


Related Product Guide:

abide by the contract", conforms towards the market requirement, joins during the market competition by its good quality likewise as provides additional comprehensive and great services for customers to let them turn out to be big winner. The pursue of your enterprise, is the clients' fulfillment for China Wholesale Double beam infrared spectrometer Suppliers – LADP-14 Determining Specific Charge of Electron – Advanced Model – Labor , The product will supply to all over the world, such as: Norwegian, Australia, Angola, Each customer's satisfactory is our goal. We are looking for long-term cooperation with each customer. To meet this, we keep up our quality and provide extraordinary customer service. Welcome to our company, we are expecting to cooperate with you.
  • We always believe that the details decides the company's product quality, in this respect, the company conform our requirements and the goods are meet our expectations.
    5 Stars By Kevin Ellyson from British - 2018.11.04 10:32
    We are long-term partners, there is no disappointment every time, we hope to maintain this friendship later!
    5 Stars By Elma from Surabaya - 2017.09.26 12:12
    Write your message here and send it to us