China Wholesale Mach-Zehnder interferometer Factory – LCP-6 Interference, Diffraction &Polarization Kit – Enhanced Model – Labor
China Wholesale Mach-Zehnder interferometer Factory – LCP-6 Interference, Diffraction &Polarization Kit – Enhanced Model – Labor Detail:
Experiments
Build Interferometers and Observe Interference Patterns
Construct a Michelson interferometer and measure the refractive index of air
Construct a Sagnac interferometer
Construct a Mach-Zehnder interferometer
Set Up Fraunhofer Diffraction and Measure Intensity Distribution
Fraunhofer diffraction through a Single Slit
Fraunhofer diffraction through a Multi-Slit Plate
Fraunhofer diffraction through a Single Circular Aperture
Fraunhofer diffraction through a Transmission Grating
Set Up Fresnel Diffraction and Measure Intensity Distribution
Fresnel diffraction through a Single Slit
Fresnel diffraction through a Multi-Slit Plate
Fresnel diffraction through a Circular Aperture
Fresnel diffraction past a Straight Edge
Measure and Analyze Polarization Status of Light Beams Brewster’s angle measurement of a black glassVerification of Malus’s LawFunction study of a half-wave plateFunction study of a quarter-wave plate: circularly and elliptically polarized light
Part List
Description | Specs/Part # | Qty |
He-Ne laser | LTS-10 (>1.5 mW@632.8 nm) | 1 |
Transversal measurement stage | Range: 80 mm; accuracy: 0.01 mm | 1 |
Magnetic base with post holder | LMP-04 | 3 |
Two-axis mirror holder | LMP-07 | 2 |
Lens holder | LMP-08 | 2 |
Plate holder | LMP-12 | 1 |
White screen | LMP-13 | 1 |
Aperture adjustable bar clamp | LMP-19 | 1 |
Adjustable slit | LMP-40 | 1 |
Laser tube holder | LMP-42 | 1 |
Optical goniometer | LMP-47 | 1 |
Polarizer holder | LMP-51 | 3 |
Beam splitter | 50:50 | 2 |
Polarizer | 2 | |
Half-wave plate | 1 | |
Quarter-wave plate | 1 | |
Black glass sheet | 1 | |
Flat mirror | Φ 36 mm | 2 |
Lens | f ‘ = 6.2, 150 mm | 1 each |
Grating | 20 l/mm | 1 |
Multiple-slit & multi-hole plate | Single slit: 0.06 & 0.1 mmMulti-slit: 2, 3, 4, 5 (slit width: 0.03 mm; center-to-center: 0.09 mm)Round holes: diameter: 0.05, 0.1, 0.2, 0.3, 0.4, 0.5 mmSquare holes: length: 0.05, 0.1, 0.2, 0.3, 0.4, 0.5 mm | 1 |
Optical rail | 1 m; aluminum | 1 |
Universal carrier | 2 | |
X-translation carrier | 2 | |
X-Z translation carrier | 1 | |
Air chamber with gauge | 1 | |
Manual Counter | 4 digits, counts 0 ~ 9999 | 1 |
Photocurrent amplifier | 1 |
Note: a stainless steel optical table or breadboard ( ≥ 900 mm x 600 mm) is needed for use with this kit.
Product detail pictures:
Related Product Guide:
We retain improving upon and perfecting our items and repair. At the same time, we perform actively to do research and progress for China Wholesale Mach-Zehnder interferometer Factory – LCP-6 Interference, Diffraction &Polarization Kit – Enhanced Model – Labor , The product will supply to all over the world, such as: Colombia, Latvia, Jordan, Our company abides by the management idea of "keep innovation, pursue excellence". On the basis of assuring the advantages of existing products, we continuously strengthen and extend product development. Our company insists on innovation to promote the sustainable development of enterprise, and make us become the domestic high-quality suppliers.
By Marguerite from Tunisia - 2018.05.15 10:52
The manufacturer gave us a big discount under the premise of ensuring the quality of products, thank you very much, we will select this company again.
By Freda from Honduras - 2018.03.03 13:09