Welcome to our websites!
section02_bg(1)
head(1)

Electrical Meters&Accessories

DC Electrical Instruments, Measuring Instruments and Accessories, etc.     

S/N Item Description Price USD              Battery power type Price USD
1 Direct current Resistance bridge  QJ23 type single-arm bridge, also known as Wheatstone bridge, portable design, accuracy 0.2, measuring range 1Ω~9.999MΩ. 175  201 
2 QJ23a, QJ24 type single - arm bridge , portable design, accuracy class 0.1,The measuring range is 1Ω~11.11MΩ. 227  276 
3 Direct current Double arm bridge  QJ42 type, Kelvin bridge, portable design, accuracy: level 2, Four-terminal measurement, the measuring range is 10 -4 ~11Ω. 183  227 
4 QJ44 type, Kelvin bridge, portable design, accuracy: 0.2 level, Four-terminal measurement, the measuring range is 10 -4 ~11Ω. 279  332 
5 Direct current Single and double arm bridge  QJ19, QJ32 DC single and double arm bridge , measuring range: 10 -5 Ω~10 6 Ω ,Excluding galvanometer, standard resistance, measured resistance 0.05 level              559  637 
6 QJ36, QJ65 DC single and double arm bridge, measuring range: 10 -6 Ω~10 7 Ω, Excluding galvanometer, standard resistance, measured resistance 0.02 level    672  751 
7    Direct current Potentiometer    UJ33a type DC potentiometer 323     384    
1. Measuring range: ×5: 0~1.0550V; ×1: 0~211.0mV; ×0.1: 0~21.10mV
2. Portable, with galvanometer and voltage reference inside;
3. Measurement accuracy: level 0.05.
8    Direct current Potentiometer    UJ36a DC Potentiometer 227     279    
1. Measuring range: ×1: 0~230mV; ×0.2: 0~46.0mV
2. Portable, with galvanometer and voltage reference inside;
3. Measurement accuracy: 0.1 level.
9    Direct current Potentiometer    UJ31 DC potentiometer (low potential) 314     358    
1. Measuring range: ×1: 0~17.1mV, ×10: 0~171mV
2. Excluding galvanometer and standard battery;
3. Measurement accuracy: level 0.05.
10 Standard battery BC9 a standard battery Electric potential: 1.01855~1.01868V, accuracy: 0.005 level 70  113 
11 Standard potential And the measured potential ZC1560 standard electric potential and measured low electric potential Standard electric potential: 1.01860V, measured electric potential: 0~190mV, stability: 0.01%/hour                             157 
12 Standard potential And the measured potential ZC1561 standard electric potential and measured high electric potential Standard potential: 1.01860V, measured potential: 0~1.90V, stability: 0.01%/hour                            157 
13 DC galvanometer   AZ19 type, sensitivity: 500 µ V/div~0.5 µ V/div, measuring range ±30μV~±30mV.  192 
14 AC5 type, sensitivity: 2 × 10 -5 A~2 × 10 -8 A/div, measuring range ±1μA~±1mA.  183 
15 AC5-1 ~ AC5-7 type, single range, sensitivity: 2 × 10 -5 A/div to 2 × 10 -8 A/div, measuring range ±1μA to ±1mA.  131 
16 Decimal capacitor box RX7-0 type, capacitance range: (0 ~ 10) × (from 0.001 from 0.0001 + + 0.01 + 0.1) [mu] F., A DC voltage 100V, AC 36V, accuracy: 0.5. Other specifications can be customized.  241 
17 Standard capacitor BR8-1 ~ 5 type, the capacitor capacity is 0.001 µ F, 0.01 µ F, 0.1 µ F, 1 µ F, 10 µ F, Withstand voltage: DC 100V, AC 36V, accuracy: 0.5 level. Other specifications can be customized.  120 
18    Decimal inductance box    GX9/1 type, inductance (0~10)×0.1mH, 10 bits in total, accuracy level 2;  166    
GX9/2 type, inductance (0~10)×1mH, 10 bits in total, accuracy level 1; 
GX9/3 type, inductance (0~10)×10mH, 10 bits in total, precision 0.5; 
GX9/4 type, inductance (0~10)×100mH, 10 bits in total, accuracy level 1. 
19  Combination Inductance box  GX8/0 type, with inductance starting from 0.1mH, 4 gears in total, 10 positions for each gear, highest precision: 0.5 level;  506  
Model GX8/1, with inductance starting from 1mH, 4 gears in total, 10 positions for each gear, highest precision: 0.5 grade. 
20 Standard inductance box BG6-1 ~BG6-5, 0.1mH~1H, precision: 0.1 grade, 0.2 grade, can be customized.  133 
21  Standard resistance  BZ3 type, accuracy: 0.01 grade; power: 0.1W, 4 terminal type, 9 pieces/set.    148/each
1310/set
22    DC resistance box    ZX21 type, 0~99999.9Ω, accuracy: 0.1 grade.  96 
ZX21a type, 0~111111.0Ω, accuracy: 0.1 grade.  122 
ZX25a type, 0.01~11111.11Ω, accuracy: 0.02 level.  349 
ZX54 type, 0.01~111111.11Ω, precision: 0.01 level.  585 
23      AC and DC Resistance box      ZX32 type, 0~11111.10Ω, 0.25W, precision: 0.05 level.  323 
ZX17-1 type, 0~111111.0Ω, 0.5W precision: 0.1 grade.    323 
ZX17-2 type, 0~1111.0Ω, 0.5W, accuracy: 0.2 level.    166 
ZX36A type, 0~11110Ω, 0.25W, accuracy: 0.1 grade.       131 
ZX38A/10 type, 0~11111.10 Ω, 0.25W, accuracy: 0.1 grade.      262 
ZX38A/11 type, 0~111111.0Ω, 0.25W, accuracy: 0.1 grade.  262 
24 High stability DC stabilized power supply ZC9101 series: Voltage 2V, 4V, 6V adjustable in stages, current 40mA, stability: 2×10 -5 /hour; 0~6V/50mA continuously adjustable, stability: 5×10 -5 /hour. customizable.  314 
25     DC stabilized current power supply     ZC9102 DC stabilized current power supply               227     
1. 0~15V continuously adjustable voltage source, allowable current 0.5A; 
2. 0~200mA constant current source, the maximum output voltage is about 15V; 
3. Positive and negative symmetrical DC power supply: Output: ±2, ±4, ±6, ±8, ±10, ±12V, allowable current 0.1A; 
4. Parameters of different specifications and performance can be customized. 
26 Stable power supply for physics experiment ZC9110 series: voltage within 0~30V, current within 0~1A, single or multiple power supply, stability: 1×10 -4 ~1×10 -5 /hour, can be customized.  175-310
27 Physics experiment low-frequency signal source ZC9120 type, 20~1000Hz sine wave, 4-digit frequency display.  223 
28 DDS signal source ZC9130 series, sine wave, square wave, triangle wave, sawtooth wave, frequency 0-6MHz, resolution 0.01Hz, expandable power output.  279 
29 Digital display DC Micro current source ZC9205 type, constant current 0~20 µ A~200mA five ranges continuously adjustable, open circuit voltage 5~15V adjustable. Stability: 1×10 -3 /hour, 3 and a half digital display.  367 
30 Digital display DC current source ZC9206 type, constant current 0~200 µ A~2A five ranges continuously adjustable, open circuit voltage 5~15V. Stability: 1×10 -3 /10min, 3 and a half digital display.  402 
31     Digital DC Microcurrent meter     ZC9301 type, 3 and a half digital display, divided into four ranges 0~200pA~200nA.  559 
ZC9302 type, three half display, sub-fourth gear range 2nA ~ 2 ~ 0 [mu] A.  489 
ZC9303 type, three half display, sub-fourth gear range 20nA ~ ~ 20 is 0 [mu] A.  402 
ZC9305 type, three half display, sub-fourth gear range 200nA ~ ~ 200 is 0 [mu] A.  384 
ZC9306 type, 3 and a half digits display, divided into four ranges of 0~2 µ A~2mA.  367 
32 AC and DC Ammeter Model ZC9310, AC and DC current measurement, 4 and a half digital display, divided into four ranges from 0 to 1.999A.  314 
33 AC and DC Voltmeter Model ZC9320, AC and DC voltage measurement, 4 and a half digital display, divided into four ranges 0~19.999V.  314 
34 Digital galvanometer ZC9350 type, 3 and a half digits display, the sensitivity is continuously adjustable, the maximum 1nA, can be customized.  279 
35 Dark box By measuring the external electrical characteristics, 4-5 different unknown electrical components can be judged.  31 
36 Knife switch  ZCDK-10 type, high quality single pole double throw switch, rated current 10A, 1mm thick beryllium bronze reed.  26 
37 ZCSK-10 type, high quality double pole double throw switch, rated current 10A, 1mm thick beryllium bronze reed.  38 
38  Plate bridge  BDQ-1 plate type single-arm bridge requires additional power supply, galvanometer, switch, etc.  166 
BSQ-1 plate type double-arm bridge requires additional power supply, galvanometer, switch, etc.  201 
39 Photocell For photoelectric effect, the spectral response range is 340-700nm.  101 
40 Frank tube Argon tube, quadrupole type, used in Frank-Hertz experiment.  101 
41 Hall film Gallium arsenide material, Hall sensitivity greater than 160mV/mA • T, including socket and substrate.  17 
42 Resistance board under test Low, medium and high resistance values ​​are suitable for single-arm bridge experiments as the resistance to be measured.  17