DC Electrical Instruments, Measuring Instruments and Accessories, etc.
S/N | Item | Description | Price USD Battery power type | Price USD |
1 | Direct current Resistance bridge | QJ23 type single-arm bridge, also known as Wheatstone bridge, portable design, accuracy 0.2, measuring range 1Ω~9.999MΩ. | 175 | 201 |
2 | QJ23a, QJ24 type single - arm bridge , portable design, accuracy class 0.1,The measuring range is 1Ω~11.11MΩ. | 227 | 276 | |
3 | Direct current Double arm bridge | QJ42 type, Kelvin bridge, portable design, accuracy: level 2, Four-terminal measurement, the measuring range is 10 -4 ~11Ω. | 183 | 227 |
4 | QJ44 type, Kelvin bridge, portable design, accuracy: 0.2 level, Four-terminal measurement, the measuring range is 10 -4 ~11Ω. | 279 | 332 | |
5 | Direct current Single and double arm bridge | QJ19, QJ32 DC single and double arm bridge , measuring range: 10 -5 Ω~10 6 Ω ,Excluding galvanometer, standard resistance, measured resistance 0.05 level | 559 | 637 |
6 | QJ36, QJ65 DC single and double arm bridge, measuring range: 10 -6 Ω~10 7 Ω, Excluding galvanometer, standard resistance, measured resistance 0.02 level | 672 | 751 | |
7 | Direct current Potentiometer | UJ33a type DC potentiometer | 323 | 384 |
1. Measuring range: ×5: 0~1.0550V; ×1: 0~211.0mV; ×0.1: 0~21.10mV | ||||
2. Portable, with galvanometer and voltage reference inside; | ||||
3. Measurement accuracy: level 0.05. | ||||
8 | Direct current Potentiometer | UJ36a DC Potentiometer | 227 | 279 |
1. Measuring range: ×1: 0~230mV; ×0.2: 0~46.0mV | ||||
2. Portable, with galvanometer and voltage reference inside; | ||||
3. Measurement accuracy: 0.1 level. | ||||
9 | Direct current Potentiometer | UJ31 DC potentiometer (low potential) | 314 | 358 |
1. Measuring range: ×1: 0~17.1mV, ×10: 0~171mV | ||||
2. Excluding galvanometer and standard battery; | ||||
3. Measurement accuracy: level 0.05. | ||||
10 | Standard battery | BC9 a standard battery Electric potential: 1.01855~1.01868V, accuracy: 0.005 level | 70 | 113 |
11 | Standard potential And the measured potential | ZC1560 standard electric potential and measured low electric potential Standard electric potential: 1.01860V, measured electric potential: 0~190mV, stability: 0.01%/hour | 157 | |
12 | Standard potential And the measured potential | ZC1561 standard electric potential and measured high electric potential Standard potential: 1.01860V, measured potential: 0~1.90V, stability: 0.01%/hour | 157 | |
13 | DC galvanometer | AZ19 type, sensitivity: 500 µ V/div~0.5 µ V/div, measuring range ±30μV~±30mV. | 192 | |
14 | AC5 type, sensitivity: 2 × 10 -5 A~2 × 10 -8 A/div, measuring range ±1μA~±1mA. | 183 | ||
15 | AC5-1 ~ AC5-7 type, single range, sensitivity: 2 × 10 -5 A/div to 2 × 10 -8 A/div, measuring range ±1μA to ±1mA. | 131 | ||
16 | Decimal capacitor box | RX7-0 type, capacitance range: (0 ~ 10) × (from 0.001 from 0.0001 + + 0.01 + 0.1) [mu] F., A DC voltage 100V, AC 36V, accuracy: 0.5. Other specifications can be customized. | 241 | |
17 | Standard capacitor | BR8-1 ~ 5 type, the capacitor capacity is 0.001 µ F, 0.01 µ F, 0.1 µ F, 1 µ F, 10 µ F, Withstand voltage: DC 100V, AC 36V, accuracy: 0.5 level. Other specifications can be customized. | 120 | |
18 | Decimal inductance box | GX9/1 type, inductance (0~10)×0.1mH, 10 bits in total, accuracy level 2; | 166 | |
GX9/2 type, inductance (0~10)×1mH, 10 bits in total, accuracy level 1; | ||||
GX9/3 type, inductance (0~10)×10mH, 10 bits in total, precision 0.5; | ||||
GX9/4 type, inductance (0~10)×100mH, 10 bits in total, accuracy level 1. | ||||
19 | Combination Inductance box | GX8/0 type, with inductance starting from 0.1mH, 4 gears in total, 10 positions for each gear, highest precision: 0.5 level; | 506 | |
Model GX8/1, with inductance starting from 1mH, 4 gears in total, 10 positions for each gear, highest precision: 0.5 grade. | ||||
20 | Standard inductance box | BG6-1 ~BG6-5, 0.1mH~1H, precision: 0.1 grade, 0.2 grade, can be customized. | 133 | |
21 | Standard resistance | BZ3 type, accuracy: 0.01 grade; power: 0.1W, 4 terminal type, 9 pieces/set. | 148/each | |
1310/set | ||||
22 | DC resistance box | ZX21 type, 0~99999.9Ω, accuracy: 0.1 grade. | 96 | |
ZX21a type, 0~111111.0Ω, accuracy: 0.1 grade. | 122 | |||
ZX25a type, 0.01~11111.11Ω, accuracy: 0.02 level. | 349 | |||
ZX54 type, 0.01~111111.11Ω, precision: 0.01 level. | 585 | |||
23 | AC and DC Resistance box | ZX32 type, 0~11111.10Ω, 0.25W, precision: 0.05 level. | 323 | |
ZX17-1 type, 0~111111.0Ω, 0.5W precision: 0.1 grade. | 323 | |||
ZX17-2 type, 0~1111.0Ω, 0.5W, accuracy: 0.2 level. | 166 | |||
ZX36A type, 0~11110Ω, 0.25W, accuracy: 0.1 grade. | 131 | |||
ZX38A/10 type, 0~11111.10 Ω, 0.25W, accuracy: 0.1 grade. | 262 | |||
ZX38A/11 type, 0~111111.0Ω, 0.25W, accuracy: 0.1 grade. | 262 | |||
24 | High stability DC stabilized power supply | ZC9101 series: Voltage 2V, 4V, 6V adjustable in stages, current 40mA, stability: 2×10 -5 /hour; 0~6V/50mA continuously adjustable, stability: 5×10 -5 /hour. customizable. | 314 | |
25 | DC stabilized current power supply | ZC9102 DC stabilized current power supply | 227 | |
1. 0~15V continuously adjustable voltage source, allowable current 0.5A; | ||||
2. 0~200mA constant current source, the maximum output voltage is about 15V; | ||||
3. Positive and negative symmetrical DC power supply: Output: ±2, ±4, ±6, ±8, ±10, ±12V, allowable current 0.1A; | ||||
4. Parameters of different specifications and performance can be customized. | ||||
26 | Stable power supply for physics experiment | ZC9110 series: voltage within 0~30V, current within 0~1A, single or multiple power supply, stability: 1×10 -4 ~1×10 -5 /hour, can be customized. | 175-310 | |
27 | Physics experiment low-frequency signal source | ZC9120 type, 20~1000Hz sine wave, 4-digit frequency display. | 223 | |
28 | DDS signal source | ZC9130 series, sine wave, square wave, triangle wave, sawtooth wave, frequency 0-6MHz, resolution 0.01Hz, expandable power output. | 279 | |
29 | Digital display DC Micro current source | ZC9205 type, constant current 0~20 µ A~200mA five ranges continuously adjustable, open circuit voltage 5~15V adjustable. Stability: 1×10 -3 /hour, 3 and a half digital display. | 367 | |
30 | Digital display DC current source | ZC9206 type, constant current 0~200 µ A~2A five ranges continuously adjustable, open circuit voltage 5~15V. Stability: 1×10 -3 /10min, 3 and a half digital display. | 402 | |
31 | Digital DC Microcurrent meter | ZC9301 type, 3 and a half digital display, divided into four ranges 0~200pA~200nA. | 559 | |
ZC9302 type, three half display, sub-fourth gear range 2nA ~ 2 ~ 0 [mu] A. | 489 | |||
ZC9303 type, three half display, sub-fourth gear range 20nA ~ ~ 20 is 0 [mu] A. | 402 | |||
ZC9305 type, three half display, sub-fourth gear range 200nA ~ ~ 200 is 0 [mu] A. | 384 | |||
ZC9306 type, 3 and a half digits display, divided into four ranges of 0~2 µ A~2mA. | 367 | |||
32 | AC and DC Ammeter | Model ZC9310, AC and DC current measurement, 4 and a half digital display, divided into four ranges from 0 to 1.999A. | 314 | |
33 | AC and DC Voltmeter | Model ZC9320, AC and DC voltage measurement, 4 and a half digital display, divided into four ranges 0~19.999V. | 314 | |
34 | Digital galvanometer | ZC9350 type, 3 and a half digits display, the sensitivity is continuously adjustable, the maximum 1nA, can be customized. | 279 | |
35 | Dark box | By measuring the external electrical characteristics, 4-5 different unknown electrical components can be judged. | 31 | |
36 | Knife switch | ZCDK-10 type, high quality single pole double throw switch, rated current 10A, 1mm thick beryllium bronze reed. | 26 | |
37 | ZCSK-10 type, high quality double pole double throw switch, rated current 10A, 1mm thick beryllium bronze reed. | 38 | ||
38 | Plate bridge | BDQ-1 plate type single-arm bridge requires additional power supply, galvanometer, switch, etc. | 166 | |
BSQ-1 plate type double-arm bridge requires additional power supply, galvanometer, switch, etc. | 201 | |||
39 | Photocell | For photoelectric effect, the spectral response range is 340-700nm. | 101 | |
40 | Frank tube | Argon tube, quadrupole type, used in Frank-Hertz experiment. | 101 | |
41 | Hall film | Gallium arsenide material, Hall sensitivity greater than 160mV/mA • T, including socket and substrate. | 17 | |
42 | Resistance board under test | Low, medium and high resistance values are suitable for single-arm bridge experiments as the resistance to be measured. | 17 |